Bd vacutainer blood collection tubes by becton, dickinson and company bd mar 23, 2018 10. Bd is recalling their vacutainer edta blood collection tubes with lavender, tan, pink and green rubber tube stoppers due to a chemical in the rubber tube stopper that interferes with the accuracy of the anodic. Fda issued recall on bd vacutainer blood collection tubes by becton, dickinson and company bd due to chemical interference with certain tests. Bd 211832 vogesproskauer vp utilized confirmatory test only. Manual and automated instrumentation for identification of. Bdhubcutter description fillcapacity boxcontent itemnumber units bdhubcutterforhypodermicneedles inaverage400600needles 32 305307 bdhubcutterforhypodermicneedlesrussianlabel inaverage400600needles 32 305309 description needledimensions isocolourcode boxcontent itemnumber units 0.
Bd leads in patient and healthcare worker safety and the technologies that enable medical research and clinical laboratories. Bd, bd logo and all other trademarks are the property of becton, dickinson and company. In 1997, bd acquired difco laboratories of detroit, michigan. Samples collected in these tubes are used for plasma determinations in chemistry for your business. Bectondickinson, 384021, bd introsyten precision introducer. Oxiferm ref bd phoenix gram negative ast nmicid qc set. Principles and explanation of the procedure microbiological method. Enterotube ii the enterotube ii, first designed and marketed by roche diagnostics in 1969, was eventually sold to becton dickinson and is used for the identification of enterobacteriaceae and four commonly isolated oxidasenegative nonfermenters.
Phoenix ref microscan dried gram negative panel qc set. Enterotube has its own enclosed inoculating wire that allows inoculation and completion of 15 standard biochemical tests for the identification of enteric unknowns. Manual of microbiological culture media becton dickinson. The enterotube ii procedure, result interpretation. Becton, dickinson and company price becton, dickinson and company quote. To provide plasma advantage, becton dickinson offers the bd rst becton, dickinson and company, franklin lakes, nj, usa. The crystal mind software can also be used under manual mode without. The bd bbl crystal identification system is a miniaturized identification system that requires only one step for inoculation. Preanalytical variables account for most of laboratory errors and there are many factors that affect and contribute to the results from a patient. Description enteropluritest is a 12sector system containing special culture media that permits identification of the enterobacteriaceae and other gram negative, oxidase negative bacteria. Newly defined, key markers include the transcription factors blimp1 and xpb1s. Unless otherwise noted, bd, the bd logo and all other trademarks are property of becton, dickinson and company. Pseudomonas aeruginosa schroeter migula atcc 27853.
Any biochemical test result obtained from the bbl enterotube ii which is cm273176. Gas positive is a definite and complete separation of the white wax overlay from the surface of the. The becton dickinson bbl enterotube ii system for identification of members of the order parag saxena 259 words view diff exact match in snippet view article find links to article school of the university of pennsylvania. Catalog number 212116 enterotube interpretation guide need 1 becton, dickinson, and company. Newly defined, key markers include the transcription factors blimp1. Product contains the same set of 25 tubes for identification of bacteria. Trademark index the trademarked terms on this list appear in vwr publications and on this web site. Apr 25, 2018 bd vacutainer edta lavender, tan, and pink top tubes bd vacutainer lithium heparin green top tube posted 03232018 audience. Also, eventually check that the organism is a gram negative rod. Bd vacutainer pst lithium heparin tubes eliminate the need to wait for a clot to form, making it an ideal tube for stat procedures, as well as for patients receiving anticoagulant therapy. The enterotube ii is an example of a rapid, multi test system used in identification of unknown oxidase negative, gram negative, rod shaped bacteria of the family enterobacteriaceae. Once inoculated, the panels provide a safe and easytohandle closed system. Bd is a global medical technology company that is advancing the world of health by improving medical discovery, diagnostics and the delivery of care.
Bd diagnostics, a segment of bd becton, dickinson and company, announces the u. This item is made in italy and distributed by becton dickenson. This product is similar to the discontinued enterotube ii. Bd vacutainer venous blood collection tube guide bd diagnostics preanalytical systems 1 becton drive franklin lakes, nj 07417 usa invert gently,do not shake the performance characteristics of these tubes have not been established for infectious disease testing in general. For the rapid identification of enterobacteriaceae. Evaluation of the bd vacutainer rst blood collection tube. Summer challenge is a 45days long competition where 20 teams with 10 people each compete to bring positive change to our society. Identifying unknown bacteria using biochemical and. Samples processed in these tubes are used for plasma. Bbl enterotube ii is a selfcontained, compartmented plastic tube containing twelve different media that allow the determination of 15 biochemical reactions glucose, gas production from glucose, lysine.
Bd phoenix automated identification and susceptibility. We do not have any document for this combination of countrylanguage and catalog number. Afterwards, inoculate a fresh bbl enterotube ii tube using wellisolated colonies. Bd, bd logo and all other trademarks are the property of becton, dickinson.
Bd vacutainer sodium heparin tubes are spraycoated with sodium heparin. An example of a commercially available manual bmd is sensititre trek diagnostic systems, cleveland, oh. Escherichia coli migula castellani and chalmers atcc. Bbl enterotube enteropluri by bd global scientific. Bd continues to support researchers by introducing innovative tools to study multiple aspects of bcell biology. The bd bbl enterotube ii incorporates 15 standard biochemical tests contained in a. Enteropluritest is a 12sector system containing special culture media that permits identification of the enterobacteriaceae and other gram negative, oxidase negative bacteria.
Bdhubcutterforhypodermicneedlesrussianlabel inaverage400600needles 32 305309 description needledimensions isocolourcode boxcontent itemnumber units 0. Fda strain seattle 1946 dsm 1103, ncib 12210 type strain. Bd is recalling their vacutainer edta blood collection tubes with lavender, tan, pink and green rubber tube stoppers due to a chemical in the rubber tube stopper that interferes with the accuracy of the anodic stripping. Gas positive is a definite and complete separation of the white wax overlay from the surface of the glucose medium. Bd is a leading medical technology company that advances human health in every corner of the world by improving medical research, diagnostics and the delivery of care. Specimen collection variables, such as, duration of fasting, time of specimen collection. Bd diagnostics diagnostic systems becton dickinson.
The bd phoenix automated identification and susceptibility testing system provides rapid, accurate and reliable detection of known and emerging antimicrobial resistance. Bd micro, guide enterotube ii interpretation guide. Escherichia coli migula castellani and chalmers atcc 25922 strain designations. Enterotube ii is a selfcontained sterile plastic tube with 12 compartments containing distinct media that permit different biochemical tests to be performed. Recheck the biocode to be certain that the biochemical profile does not contain a positive result for both phenylalanine deaminase and dulcitol. The bd vacutainer one use holder is a quality, lowcost single use holder that can help customers comply with osha regulations. The readytouse product has been designed to help protect healthcare workers from accidental needlestick injuries nsis during the blood collection process and to prevent. Reagent addition and oil overlay are completely eliminated by the panel design.
Microorganism is identified evaluating the color change of the different culture media after 1824 hours of incubation at 36 1 c and by a code number obtained from biochemical reaction interpretation. Bd leads in health care safety including medication safety, health care worker safety and infection prevention as well as the technologies that enable medical research and. The bd bbl enterotube ii incorporates 15 standard biochemical tests contained in a unique, readytouse, compartmented tube designed to permit the simultaneous inoculation of 12 test media. Today, bd is one of the largest microbiology companies.
Formerly known as the bd bbl bd enterotube ii, it has been renamed as the bd bbl enteropluri. Becton dickinson bd is a global medical technology company that is advancing the world of health by improving medical discovery, diagnostics and the delivery of care. Find link is a tool written by edward betts becton dickinson is a redirect to bd company. Bd material safety data sheets msdss will also be referred to as safety data sheets sdss to align with global harmonization standards ghs and the newly approved may 28, 2010 american national standards institute ansi, standard z400. It also enables workflow efficiency by utilizing automated nephelometry. The bbl bd enterotube bd bbl enteropluri is a selfcontained, compartmented plastic tube which contains 12 different growth media and an. Oct 15, 2014 bd sst ii advance tube becton, dickinson and company, franklin lakes, nj, usa requires a minimum clotting time of 30 minutes prior to centrifugation to obtain serum. Bd, bd logo and bbl are trademarks of becton, dickinson and company. Aiming to benefits more than 5000 physicallychallenged and underprivileged people, each year pdf organize this event. This item has been discontinued by the manufacturer and is no longer available. Manual of clinical microbiology 1985, 4th edition asm. The first edition, published in 2003, replaced the difco manual, 11th ed.
Mck48152800 becton dic tube holder bd vacutainer standard size, clear, nonstackable, single use, 250 shelf pack for mm and 16 diameter tubes 3. The enteropluri contains 24 prepared multimedia tubes. In june 1997, bd announced the acquisition of difco laboratories, inc. In 1955, bd acquired the baltimore biological laboratory bbl of baltimore, maryland, and used its expertise to continually advance the clinical market with prepared media and diagnostic tools. The becton dickinson bbl enterotube ii system for identification of members of the order parag saxena 259 words view diff exact match in snippet view article find. Feb, 2018 becton, dickinson and company price becton, dickinson and company quote. Bd vacutainer edta lavender, tan, and pink top tubes bd vacutainer lithium heparin green top tube posted 03232018 audience. Catalog number 231746 enterotubes ii need 5 or less becton, dickinson, and company. Enteropluritest identification system of enterobacteriaceae and other gram negative, oxidase negative bacteria.
The system allows the simultaneous inoculation of all media present in the sectors and the. Identifying unknown bacteria using biochemical and molecular. Former bd bbl enterotubes item 211832 now bd bbl enteropluri item 215336. Bd bionutrients technical manual a manual dedicated to products used in cell. Bd enterotube becton, dickinson and company bd express becton, dickinson and company bd ez scrub becton, dickinson and company. Catalog number 211832 oxiferm tubes ii need 5 or less becton, dickinson, and company. Bd vacutainer venous blood collection tube guide bd diagnostics preanalytical systems 1 becton drive franklin lakes, nj 07417 usa invert gently, do not shake the performance characteristics of these tubes have not been established for infectious disease testing in general. Enterotube has its own enclosed inoculating wire that allows inoculation and completion of 15 standard biochemical.
Bd offers broths and reagents for the bd phoenix automated identification and susceptibility testing system. Bd phoenix automated identification and susceptibility testing system. Bd 1 becton drive franklin lakes, nj usa 07417 201. Enteropluritest enterotube replacement medix, your on. Bd announces launch of bd vacutainer push button blood. This holder is compatible with bd vacutainer eclipse blood collection needles, bd vacutainer safetylok blood collection sets, and the bd vacutainer multiple sample luer adapters. The results of this oxidase test determine if students use an enterotube or an oxiferm tube in the next. Bcell biology and phenotypes using bd biosciences flow cytometry products, including instruments, reagents, and protocols. Quality of a specimen depends of preanalytical variables like specimen collection, physiologic and endogenous interference factors 1,2. The selfcontained, compartmented plastic tube contains 12 conventional media and an inoculating wire.
1249 460 119 161 1065 408 1391 64 1496 234 1163 623 73 888 94 1285 662 748 1279 393 134 802 754 654 1069 1242 552 1102 1325 1253 196 1277 469 1247 887 343 1289 542 584